Case study · Geoscience & subsurface studies
For a French national geological survey, IRIAN Mecatronics designed and built a custom test cell to visualize the internal deformation of rock samples in 3D and in real time. The equipment simulates deep geological conditions (20 MPa, 150°C) while remaining transparent to X-rays for non-destructive tomographic analysis.

At a glance
01 — The research question
Characterizing how materials behave under thermo-mechanical stress often requires multiple destructive tests to reconstruct a sequence of events after the fact. Ideally, phenomena like micro-cracking or fluid flow could be observed continuously, inside the sample, as conditions are applied. This is the goal of in-situ 3D imaging, an approach that opens new research avenues in geoscience and subsurface studies. In this project, the goal was to visualize the internal deformations of a rock subjected to the pressure and temperature of deep geological reservoirs using X-ray tomography. Standard equipment faces a physical contradiction here: the metal cells capable of holding high pressure and temperature are inherently opaque to X-rays, making direct observation impossible.
To design a pressure vessel that can contain high pressure and temperature while being transparent enough to X-rays to allow 3D tomographic analysis of the sample inside.
02 — Our approach
The difficulty was finding a material that could withstand 20 MPa (2,900 psi) and 150°C (302°F) while being nearly transparent to X-rays—two properties that are usually mutually exclusive. We selected a composite material for the cell body, which combines the strength of high-performance fibers with the low X-ray attenuation of a polymer matrix. This allows the user to obtain high-quality 3D images without interrupting the test.
The metal end caps and pistons had to integrate fluid circuits and heating, but their mass could cast a shadow on the image. The solution was to use a high-specific-strength alloy to minimize their volume. Unlike standard steels, this design maximizes the area of the sample visible to the tomograph, enabling a more complete analysis.
Running sensor cables (for pore pressure and temperature) through the vessel wall at 20 MPa (2,900 psi) without leaks or metallic artifacts on the image was a critical issue. We developed custom-made, sealed feedthroughs designed for a minimal radiographic signature. This allows the user to correlate reliable physical measurements with real-time 3D imaging.
The system needed to reach 150°C (302°F) uniformly within a confined volume, without interfering with the equipment's 360° rotation. Instead of external heating with high thermal inertia, we integrated the heat sources directly into the metal parts in contact with the sample. The user benefits from rapid temperature ramp-up and precise control, ensuring the validity of the test conditions.
03 — Technical specifications
| Confining pressure | Up to 20 MPa (2,900 psi), hydrostatic |
|---|---|
| Sample temperature | Up to 150°C (302°F) |
| Compatible analysis technique | In-situ 3D X-ray tomography |
| Internal instrumentation | Pore pressure and temperature sensors close to the sample |
04 — Other applications
A common challenge is the in-situ study of micro-crack formation in a composite or alloy under stress. The principle of an X-ray transparent vessel, pressure and temperature control, and non-destructive 3D analysis would remain the same.
The goal is to visualize phase changes or swelling in storage materials during cycles under pressure and temperature. The need to contain a gas, control temperature, and perform 3D imaging during operation, as in our custom CCUS reactors, is a shared requirement.
This involves observing the growth of synthetic tissue or the degradation of an implant in a bioreactor simulating physiological conditions. Non-destructive 3D analysis over time, temperature control, and fluid management are directly transferable principles.